TechPoint: On-Premise access control without
Cloud-based forced and without servers

TechPoint is an access controller that stores management, permissions, and bookings directly on the device. It is configured in a web browser and powered by PoE+. Up to 64 controllers can be networked without a server, and there are no annual license fees for operation.

TechPoint access controller, open, with connection terminals for doors, relays and RS485

TechPoint at a glance

12 doorsper controller: 4 directly, 8 via OSDP I/O modules
64 ControllersTotal number of connections: 1 master, 63 slaves, no servers
500.000Passport holders
1.500wireless offline doors, plus up to 16 online doors
since 2014In use, in more than 10 countries, 7th hardware generation
0 €annual license fee (cloud browsing is subject to license fees)

Your access control remains in your building

Many access systems are now moving their intelligence to the cloud. That’s convenient – as long as everything works smoothly. If the provider goes out of business, changes their licensing model, or the contract ends, the security technology in your building suddenly becomes unavailable.

TechPoint takes the opposite approach. All access management is integrated into the controller: the database, configuration interface, and authorization logic run on the device itself. You don’t need a server in the rack, PC software on a workstation, or a cloud subscription.

This brings three things to mind that are important in the workplace:

  • Data sovereignty. Personal access data does not leave your network. This significantly simplifies the data protection review, as no third-party processor or third-party transfer is involved.
  • No ongoing license costs. You pay for the hardware, not the permission to use it.
  • Independence from the Internet connection. Access works when the line fails – more on that later.

Cloud functionality does not rule that out. Anyone who wants remote access, app usage, or notifications can turn them on. The difference is that they remain an addition and are not a prerequisite for the doors to work.

Access control that can be managed effortlessly

Master-slave topology: what happens in the event of a failure

Each TechPoint stores permissions and bookings itself. Several controllers work as a master-slave combination: The master manages the permissions centrally, each slave controls its doors with its own permission data. Up to 63 slaves are attached to a master; a higher-level server is not necessary.

Network failure

The Slaves continue to operate with their local permissions. Bookings are transferred to the Master after restoration.

Master's failure

The doors remain functional. A replacement device (Cold Standby) takes over, or a slave is redefined as the master. This takes about five minutes.

Power supply

TechPoint is powered via PoE+ or an external power supply. The power supply can be secured via a UPS.

Event storage

Each controller stores up to 1,000,000 events locally. The oldest entries are overwritten.

Several buildings

Each building gets its own master-slave group.

On-Premise, Cloud or Server: the comparison

Access control can be operated in three ways. The difference lies in where the data and administration are located and what happens in the event of a disruption.

CriteriaTechPoint (On-Premise in the controller)Cloud access controlClassic with a server
Where are permissions and bookings located?In the controller, in the buildingWith the provider in the cloudOn a server at the customer's premises
Do you need the Internet for operation?NoFor the administration, yesNo
Do you need servers and PC software?NoNoYes: Servers, software, database
Ongoing costsNo annual license fee; API connection is subject to licenseMost often a subscription per door or userOften software licenses and maintenance contracts
In the event of a network failureSlaves continue to work with local permissionsDepending on the manufacturerControllers mostly autonomous; central administration falls away
Remote accessOptionally via TechPoint Cloud and AppCore functionVia VPN or client software
Data protectionData remain in the buildingUsually a contract for order processing with the providerData with the customer

The information about cloud and server systems describes typical characteristics; individual manufacturers deviate from these.

Integrations

TechPoint relies on open protocols and uses readers, wireless locks, and existing security technology.

Readers

Readers are connected via OSDP via RS485, up to 8 per door; typically 1 to 2. Suitable readID readers from Security Engineering can be found under Readers & Peripherals.

Wireless doors with SimonsVoss SmartIntego

TechPoint manages up to 16 wireless online doors and up to 1,500 offline doors. For wireless doors, we work with SimonsVoss SmartIntego, which can be fully integrated into TechPoint.

Logo of SimonsVoss

Burglar alarm system and video surveillance

TechPoint integrates with burglar alarm and video surveillance systems. Alarms can be transmitted to control centers via the SIA DC-09 system.

IT systems via the API

Room booking, building management or parking systems are connected via the TechPoint API. The API connection is subject to a license fee.

Options

TechPoint Cloud and App for remote access as well as 4G mobile telephony for alarms via SMS and email are available as optional extras.

Investment protection instead of throw-away technology

Long-term viability also depends on who owns the system. Since TechPoint operates without license and subscription fees, an installed system remains operational regardless of future pricing models. This is not a given with cloud-based systems: In these cases, the functionality of the hardware ends with the contract.

For builders and planners

We support security technology developers and planners from system design to tender.

Downloads

Partner program for builders

  • Planning support for your projects
  • Earlier access to new features
  • Participation in product ideas
  • Listing as TechPoint partner

Product webinar

Next date: 30.11.2026, 10:00 a.m.
Registration at:

Manufacturer and contact person

References and applications

Further references

Technical data

DoorsCabled4 doors directly, plus 8 doors via OSDP-I/O modules (SE 600-0 or TPA-IO1)
DoorsWirelessup to 16 online doors, up to 1,500 offline doors
ReadersAnnexationOSDP via RS485, up to 8 readers per door (usually 1–2)
CapacityPassport holdersup to 500,000
CapacityEvent storage1.000.000
CapacityTimetables1.000
NetworkingMaster-Slaveup to 64 controllers per bundle (1 master, 63 slaves)
Inputs and outputsSurveillance entrances6, 2/3/4-state monitoring, analog or digital, max. 40 V DC
Inputs and outputsDigital inputs2 (5 V DC)
Inputs and outputsRelais4 (NO, NC, C), 10 A at 250 V AC / 30 V DC
Inputs and outputsOpen-drain outputs3, max. 750 mA
SupplyEntrancePoE+ (IEEE 802.3at), PoE (IEEE 802.3af) or 14–30 V DC
SupplyPower consumptionTypical 1.4 W, max. 1.9 W
SupplyOutputs for peripherals12 V DC, max. 1,800 mA; with PoE 24 V DC, max. 900 mA
NetworkSecurityIEEE 802.1X, TLS 1.3, HTTPS, IP address filtering, password-protected user levels
NetworkProtocolsIPv4, IPv6, HTTP, HTTPS, SFTP, SMTP, SNMP, DNS, SNTP
NetworkAlarm transmissionSIA DC-09
HardwareProcessor and memoryARM Cortex-A8, 128 MB RAM, 8 GB Flash, microSD slot
HardwareDimensions210 × 140 × 50 mm (H × W × T)
HardwareWeight0.65 kg
HardwareHousingAluminium, RAL 9002 and RAL 9006, optical sabotage contact
HardwareAssemblyWall mounting, bracket optional
SurroundingsOperating temperature0 to 50 °C, 20–80 % relative humidity, non-condensing
SurroundingsProtection classIP20
Functional overview TechPoint with management in the browser, OSDP readers, wireless doors, optional cloud and 4G

Frequently asked questions about TechPoint

Answers to the questions that developers, planners and operators most frequently ask.

Which buildings are suitable for TechPoint?

Does TechPoint work without the cloud?

Yes. Administration and the database are located in the controller. Cloud features such as remote access and apps are optional.

Is a server or PC software required?

No. TechPoint is set up and managed via the integrated interface in the web browser.

Are there any ongoing license fees?

Not for operation; there is no license or subscription model. Only the connection to external systems via the API for cloud browsing and the app is subject to a license fee.

How many doors does a TechPoint control?

4 doors directly and 8 more via OSDP-I/O modules, that is 12 wired doors per controller. In addition, there are up to 16 wireless online doors and up to 1,500 offline doors.

How many controllers can be connected together?

Up to 64 in a cluster: 1 master and 63 slaves. Larger systems are divided into several groups.

Will access control work in the event of a network failure?

Yes. The slaves continue to work with their local permissions; bookings are transferred after the restore.

What happens if the master fails?

The doors remain functional. A replacement device takes over or a slave is redefined as the master; this takes about five minutes.

How many access events does TechPoint store?

Up to 1,000,000 per controller. The oldest entries are overwritten.

Which readers can I connect to?

All OSDP readers via RS485, up to 8 per door. We recommend the readID readers from Security Engineering.

Can wireless locks be integrated?

Yes. For wireless online and offline doors, we work with SimonsVoss SmartIntego, which can be fully integrated into TechPoint.

How is TechPoint supplied with electricity?

Via PoE+ or PoE over the network cable, or with 14–30 V DC. The power supply can be secured via a UPS.

What security standards does TechPoint support?

OSDP for reader connectivity, TLS 1.3 and HTTPS for encrypted communication, IEEE 802.1X for network access control, and SIA DC-09 for alarm transmission.

Are there tender documents?

Yes, feel free to contact us about that.

Who creates TechPoint?

TechPoint is developed by TechSolutions and has been in use since 2014. Sales and planning support in Germany, Austria and Switzerland is provided by TechSolutions Germany GmbH in Furtwangen.

How do I become a TechPoint partner?

Through the contact form or by email to info@techsolutions.de. Partners receive planning support, early access to new features, and are listed as TechPoint partners.

Talk to us about your access concept